Skip to main content
Free Delivery  ·  COD Available  ·  15-Day Returns
Pricio
Renke RS-NH3-N01-2-100P-2-YL-EX, Ammonia sensor (for livestock farm using) , RS485, Range: 0~100ppm — image 1
Hover to zoom

1 / 3 · Click to enlarge

Renke

Renke RS-NH3-N01-2-100P-2-YL-EX, Ammonia sensor (for livestock farm using) , RS485, Range: 0~100ppm

35+ bought in past month
AI Summary
Gas Sensors for premium buyers

The Renke RS-NH3-N01-2-100P-2-YL-EX, Ammonia sensor (for livestock farm using) , RS485, Range: 0~100ppm by Renke is a premium gas sensors designed for premium buyers. It features Item Type: Ammonia Sensor and Model No. / Name: RS NH3 N01 2 100P 2 YL EX.

₹17,184
Free Shipping💵 COD Available

Available Offers

Free Delivery on this order. No minimum order value.

15-Day Easy Returns — hassle-free return & full refund.

Secure Payment — 100% safe checkout with UPI, Cards & Net Banking.

Total: ₹17,184
Buying tip: A top-tier option — the best features and quality available in this category.
Estimated delivery: 17 Aug31 Aug
Free Shipping
Pan India delivery
15-Day Returns
Hassle-free policy
Secure Payment
Razorpay protected
Quality Assured
Vetted products only

Available Offers

💳

5% Cashback

Pay with UPI & get 5% cashback (up to ₹50) via Razorpay

🏦

No-Cost EMI

Available on select bank cards at checkout. 0% interest for 3 months.

📦

Free Shipping

Free delivery on all orders. No minimum order value.

💵

Cash on Delivery

COD available on orders up to ₹5,000 across India.

Quick Specs

Item Type: Ammonia Sensor
Model No. / Name: RS NH3 N01 2 100P 2 YL EX
Power Supply Voltage (V): DC 10–30 V
Accuracy: ±8% (0–50ppm/0–100ppm), ±5%FS (0–500ppm @100ppm, 25℃, 50%RH)
Resolution: 0.1ppm (0–50ppm), 1ppm (0–100ppm/0–500ppm)
Operating Temperature (°C): -20 to 50

Ideal For

Electronics projectsArduino / Raspberry Pi buildsPrototyping
Share:
SKU: robu-3017690Category: Gas Sensors

About This Product

The Renke RS-NH3-N01-2-100P-2-YL-EX, Ammonia sensor (for livestock farm using) , RS485, Range: 0~100ppm by Renke is a premium gas sensors designed for premium buyers. It delivers reliable performance at an accessible price.

Key Specifications

  • Item Type: Ammonia Sensor
  • Model No. / Name: RS NH3 N01 2 100P 2 YL EX
  • Power Supply Voltage (V): DC 10–30 V — works with standard household power
  • Accuracy: ±8% (0–50ppm/0–100ppm), ±5%FS (0–500ppm @100ppm, 25℃, 50%RH)
  • Resolution: 0.1ppm (0–50ppm), 1ppm (0–100ppm/0–500ppm)
  • Operating Temperature (°C): -20 to 50
  • Humidity Range: 15%RH ~ 90%RH — reliable connection even at a distance
  • Pressure Range (MPa): 90~110kPa — reliable connection even at a distance

Why Buy from Pricio?

Pricio sources this product directly, cutting out multiple middlemen. Every order includes free shipping, a 15-day return policy, and secure payment via Razorpay.

The RS-NH3--2--EX Ammonia Sensor is a high-precision industrial-grade device designed for reliable ammonia gas detection in diverse environments. Featuring selectable measuring ranges of 0–50ppm, 0–100ppm, and 0–500ppm, it meets the needs of animal husbandry, production plants, and industrial monitoring. Its waterproof wall-mounted design ensures durability and space efficiency. With multiple output options including RS485, 0–5V, 0–10V, and 4–20mA, it offers seamless integration with various control systems. Optional temperature and humidity measurement, OLED display, and a wide 10–30V DC power supply make it versatile, accurate, and ideal for continuous monitoring in harsh conditions.


Features:

  1. Multiple measuring ranges: 0–50ppm, 0–100ppm, 0–500ppm
  2. High measurement accuracy and repeatability within 2%
  3. Supports RS485, 0–5V, 0–10V, and 4–20mA outputs
  4. Waterproof, wall-mounted industrial design
  5. Optional OLED display for real-time readings
  6. Wide 10–30V DC power supply for flexible installation

Application:
  1. Industrial ammonia gas monitoring
  2. Livestock and poultry farm air quality control
  3. Chemical and fertilizer plant safety systems
  4. Refrigeration and cold storage leak detection
  5. Environmental and laboratory gas analysis
  6. Waste treatment and composting facility monitoring

Package Includes:

1 x Renke RS-NH3-N01-2-100P-2-YL-EX, Ammonia sensor (for livestock farm using) , RS485, Range: 0~100ppm

Setup Guide

1
Identify the pins
Locate VCC (power), GND (ground), and data pins (SDA/SCL for I2C, MOSI/MISO for SPI, or TX/RX for UART). Refer to the pinout diagram on the product page.
2
Wire to your microcontroller
Connect VCC to 3.3V or 5V (check the module spec), GND to GND, and data pins to the appropriate GPIO pins on your Arduino or Raspberry Pi.
3
Install libraries
In Arduino IDE, go to Sketch → Include Library → Manage Libraries and search for the sensor library. Install the recommended version.
4
Upload example sketch
Open File → Examples → [library name] → Basic Example. Upload to your board and open Serial Monitor to view output.
5
Calibrate if needed
Some sensors (temperature, humidity, distance) may need a short warm-up period or calibration. Run the calibration sketch if provided.